Steam traps
With GESTRA bimetallic, ball float, thermostatic capsule and thermodynamic steam traps, we ensure efficient, uninterrupted condensate drainage in your steam lines.


Steam trap series
Four main series to suit your process conditions; the operating data and example models of each series are shown below.

BK 45
BK 29
BK 212
BK 15
BK 45 installation
Bimetallic typeBK series bimetallic steam traps
Bimetallic steam traps operate on the thermostatic principle and are used especially in applications such as turbine drainage, superheated steam and tracing lines.
- Differential pressure
- 0.1–275 bar
- Pressure rating
- PN630 · Class 2500
- Max. temperature
- 650 °C
- Capacity
- 80–6,000 kg/h
- Body and cover
- F12, F22, F91

UNA 14h
UNA 38
UNA 45
UNA 45h
Ball float typeUNA series ball float steam traps
A steam trap type that can be used in almost every application in steam systems, is unaffected by back pressure and has a high air-venting capacity; it ensures continuous condensate drainage, especially for equipment with high steam consumption.
Even if the float ball is deformed by water hammer, it rotates around its own axis to close the orifice and ensure a tight seal.
- Differential pressure
- 0.1–140 bar
- Max. temperature
- 550 °C
- Capacity
- 80–100,000 kg/h
- Monitoring
- Integrated sight glass

MK 45/1
MK 45
Application
Installation
Thermostatic capsuleMK series thermostatic capsule steam traps
These steam traps respond very sensitively to the condensate formed, and their operation is not affected by the installation position or the inlet pressure.
The Hastelloy® capsule – the heart of the steam trap – and all internal parts are made of corrosion-resistant material and withstand even condensate containing acids and chlorine.
- Differential pressure
- 0.6–32 bar
- Pressure rating
- PN40 · Class 300
- Max. temperature
- 425 °C
- Capacity
- 15–9,000 kg/h

DK 47
DK 47 L
Field application
ThermodynamicDK series thermodynamic steam traps
Thermodynamic steam traps have a simple design and compact dimensions and are resistant to water hammer and freezing.
At the end of condensate discharge, the velocity of the steam passing under the disc increases and its pressure drops, and the pressure building up behind the disc closes the trap. Because of this operating principle, a small amount of steam is lost during operation.
- Differential pressure
- 0.7–42 bar
- Pressure rating
- PN63 · Class 600
- Max. temperature
- 450 °C
- Capacity
- 60–2,000 kg/h
Other product groups
Steam trap testing deviceLeak testing and reporting with VKP 41
Condensate return monitoring systemsCondensate monitoring with OR 52 and ORGS 11-2
Non-return valvesRK, BB and CB series non-return valves- ValvesAK 45 automatic drain valve
Modulating level control systemsNRGT 26-2 capacitance level electrode
Continuous blowdown control systemsLRGT, LRGS and LRG series electrodes
Intermittent blowdown control systemsMPA series valve and TA series controller
Low / high level limitingNRG electrode and NRS controller
On / off level controlNRGS and NRS series level control
Request a quote for GESTRA steam traps
Share the model, connection size, differential pressure and condensate capacity, and let’s define the right steam trap together.